Skip to main content
Follow us on: 
PLATES & GASKETS

Gasket Selection.

Provide the following information to our THS sales team for a quote at Contact THS SERVICE or 905-831-4963.

  • 1.
    Manufacturer
  • 2.
  • 3.
    Application (Water, Steam, Glycol)
  • 5.
  • 6.
    Quantity
  • 7.
    Type
  • 8.
    Nameplate Image

Model Finder

  1. Measure the center to center mm of the port holes horizontal (A) and vertical (B).

  2. Choose Manufacturer for model chart 

ALFA LAVAL (cont'd] Gaskets

ALFA LAVAL (cont'd] Gaskets

Model A 10 A 10 B AM 10 A 15 A 15 B  A 15 BW
A = mm 290 234 290 350 350  350
B = mm 1205 703 1046 1315 1315  1315
             
Model A 20 A 20 B AK 20 AK 200 AM 20 AM 20 B
A = mm   430 365 365 365 365
B = mm   1550 930 930 1450 1450
             
Model A 30 A 35 AX 30 A 45 P 01 P 2 / P22
A = mm 540 765 540   60 135
B = mm 1845 1850 1836   357 591
             
Model T 5 M
FG
TS 6
FM FG
TL 6 B
FM FG FD
TL 10 B
FM FG FD
TL 15 B
FM FG FD FS
TL 35 B
FM FG FD FS
A = mm 100 203 150 225 288 578
B = mm 553 380 1036 1338 2035 2177
             
Model TS 20 M
FM FG FSFM
T 20 B
FM FG FS
T 20 M
FM FG FS
T 20 S
FG
   
A = mm 363 353 353 353    
B = mm 698 1478 1478 1478    
             
Model V4 V8 V13 V20 V28 V45
A = mm 62 100 130 130 234 234
B = mm 430 553 625 875 882 1302
             
Model V60 V110 V130 V170 H7 H10
A = mm 540 600 480 700 254 348
B = mm 1280 1320 1650 1650 1054 1221
             
Model Clip 6 Clip 8 Clip 10 EC 500 EC 700 MA 30M
A = mm 130 220 324     555
B = mm 859 1095 1324     1221

Material

Selecting the wrong gasket can be a timely and costly mistake. Let our experienced THS sales team recommend the most durable and cost effective gasket material for your application by providing us with the pressure, temperature and process liquid details.

Buna (NBR/Nitrile), EPDM or Viton materials are the most common plate & frame heat exchanger gaskets depending on the operating application.

Food Grade
Standard Grade
Aggressive Chemical Compounds

Changes in Gaskets:

  • Time – Relaxes
  • Temperature – Deteriorates
  • Oxidizing Agents – Hardens
  • Swelling – Chemical Absorption

Gaskets Material Depends on:

  • Fluids Used
  • Temperature and Pressure

Standard Gasket Styles

Clip - will usually have rubber tabs that are visible from the outside of the heat exchanger

Glue – no tabs and in most cases the brown glue is visible under the gasket; typically used in high pressure or high temperature applications

Ball - used in HVAC or FDA applications to allow for easy removal in the field 

WHEN SHOULD A PLATE & FRAME HEAT EXCHANGER BE SERVICED?

As a heat exchanger becomes fouled with dirt, debris or scale, often the modulating valve provides additional hot or cold liquid to help compensate for the loss of efficiency of the heat exchanger.

Over time the control valve will continue to open fully. Unfortunately, on the hottest or coldest days, even with the valve fully open the heat exchanger cannot meet the thermal transfer requirements and the situation becomes critical.

Monitoring just the operating temperature provides a false sense of security. Recording the difference in the outlet and inlet pressures provides a more accurate result of the amount of fouling.

Fouling equal to the thickness of a piece of paper represents a 20% loss of thermal efficiency. In addition, the energy cost for pumps increases since the pump must work harder to overcome the increased pressure resistance through the PHE

T.H. Industrial Solutions Inc. (THS) has been servicing industrial plate and frame heat exchangers as with shell and tube heat exchangers.  Professionally solving process problems across Canada since 2009. THS head office is located in Pickering, Ontario with a 6,000 square foot service center in Hamilton, Ontario.

Today there are fewer qualified people in this industry that know the products and understand the applications. Utilizing hands on experience and knowledge that has been gained by our THS sales and service technicians for over the past 30 years, we will take the time to understand what you require and strive to provide a prompt, educated and accurate response at a competitive price.

Our Heat Exchanger Cleaning Services, along with heat exchanger gasket replacement systems, and knowledge of heat exchanger gasket materials make THS your Industrial Heat Exchanger Service Solution

THS Logo
HEAD OFFICE

1550 Bayly Street, Unit 15
Pickering, ON L1W 3W1

T 905 831-4963

SERVICE CENTER

76 Harlowe Road, Unit 5, 6 & 7
Hamilton, ON L8W 3R6

T 905 318-0777
F 905-318-8422

Contact THS SERVICE


Proudly Canadian logo

©2024 T. H. Industrial Solutions Inc.  SITEMAP