Danfoss XGC C054P.

Danfoss XGC C054P

DATA SHEET

Danfoss XGC C054P

Plate heat exchanger

SThe Plate Heat Exchanger has 4 connections as standard and should be installed with min. 1000 mm space on both sides for service work.
Subject to alterations without prior notice

Technical Data

Dimensions, mm
Standard connection dimension    DN150
Tightening bolt                                     M39
No. of long tightening bolts (TL)       4
No. of short tightening bolts (TS)     4
Cover thickness                                   50 mm
Weight of guiding bar                        11 kg/m
Weight of reinforced guiding bar    17 kg/m
Weight of tightening bolt                   8,1 kg/m
A-dimension                                         2,1*n mm
C-dimension                                         LG+56 mm
F-dimension                                          LG+6 mm
Weight plate+gasket
     (W) AISI 304/316 0,4 mm                 1,92kg
     Titanium 0,4 mm                              1,11 kg
Weight Frame                                        880+n*W kg

Max No of plates     LTL       LG       C         F
              69                500    600    656    606
              88                750    600    656    606
              128               750    1000   1056   1006
              183               1050   1000   1056   1006
              200              1050   1350   1406   1356
              266              1350   1350   1406   1356
              271                1350   1550   1606   1556
              314               1650   1550    1606   1556
              342              1650   1900   1956   1906
              397              1950   1900   1956   1906
              414               1950   2250  2306  2256
              480             2250  2250   2306  2256
              485             2250  30001) 3056  3006
              659             3000  30001)  3056 3006

LTL = Length of long tightening bolt, based on 4,2 x n + 210 mm
LG = Length of guiding bar, based on 4,2 x n + 230 mm
n = number of plates

Total max no. of plates
AISI 304/316 0,4 mm      700

Total min no. of plates
AISI 304/316 0,4 mm     30

 

     1) LG>2372 mm reinforced guiding bar Height+60mm.

All data is based on plates with material AISI 304/316 and thickness 0,4 mm.

Ontario service representative for Armstrong Plate & Frame and Shell & Tube Exchangers.

Ontario service representative for Caron et files Custom Industrial Heat Exchangers, Heater Coils, Steam Unit Heaters

Ontario service representative for Bray Butterfly Valves, Bray Ball Valves, Bray Check Valves, Bray Knife Gate Valves, Bray Actuators – Electric, Manual & Pneumatic Solenoids

Ontario service representative for Puroflux line of Permanent Media Filters, Centrifugal Separators and Disc Filters.

Ontario service representative for Filter Solutions Inc. line of Magnetic Separators, Bag and Cartridge Housings and Wedge Wire Filters & Strainers.

Ontario service representative for REOTEMP Instruments line of Pressure Gauges, Bi-Metal Thermometers and RTDs

Ontario service representative for Clearstream Filters line of Self-Cleaning Indexing Media Filters and Custom Filter Bags

Ontario service representative for Xylem, Bell & Gossett Plate & Frame and Shell & Tube Exchangers. Ontario Service representative for TTP (API Heat Transfer Company) Oil Coolers.

Ontario Service representative for SWEP (A Dover Company) Brazed Plate Heat Exchangers.

Ontario Service representative for Kelvion Brazed Heat Exchangers, Plate & Frame Heat Exchangers, and Shell & Tube Heat Heat Exchangers.

WHEN SHOULD A PLATE & FRAME HEAT EXCHANGER BE SERVICED?

As a heat exchanger becomes fouled with dirt, debris or scale, often the modulating valve provides additional hot or cold liquid to help compensate for the loss of efficiency of the heat exchanger.

Over time the control valve will continue to open fully. Unfortunately, on the hottest or coldest days, even with the valve fully open the heat exchanger cannot meet the thermal transfer requirements and the situation becomes critical.

Monitoring just the operating temperature provides a false sense of security. Recording the difference in the outlet and inlet pressures provides a more accurate result of the amount of fouling.

Fouling equal to the thickness of a piece of paper represents a 20% loss of thermal efficiency. In addition, the energy cost for pumps increases since the pump must work harder to overcome the increased pressure resistance through the PHE

T.H. Industrial Solutions Inc. (THS) has been servicing industrial plate and frame heat exchangers as with shell and tube heat exchangers.  Professionally solving process problems across Canada since 2009. THS head office is located in Pickering, Ontario with a 6,000 square foot service center in Hamilton, Ontario.

Today there are fewer qualified people in this industry that know the products and understand the applications. Utilizing hands on experience and knowledge that has been gained by our THS sales and service technicians for over the past 30 years, we will take the time to understand what you require and strive to provide a prompt, educated and accurate response at a competitive price.

Our Heat Exchanger Cleaning Services, along with heat exchanger gasket replacement systems, and knowledge of heat exchanger gasket materials make THS your Industrial Heat Exchanger Service Solution

THS Logo
HEAD OFFICE

1550 Bayly Street, Unit 15
Pickering, ON L1W 3W1

T 905 831-4963

SERVICE CENTER

76 Harlowe Road, Unit 5, 6 & 7
Hamilton, ON L8W 3R6

T 905 318-0777
F 905-318-8422

Contact THS SERVICE


Proudly Canadian logo

©2024 T. H. Industrial Solutions Inc.  SITEMAP